![]() ![]() (iv) an alteration to any part of the roof of the dwellinghouse.Ī.2 In the case of a dwellinghouse on article 2(3) land, development is not permitted by Class A if. (iii) the installation, alteration or replacement of a chimney, flue or soil and vent pipe, or (ii) the installation, alteration or replacement of a microwave antenna, (i) the construction or provision of a verandah, balcony or raised platform, (iii) have a width greater than half the width of the original dwellinghouse or (j) the enlarged part of the dwellinghouse would extend beyond a wall forming a side elevation of the original dwellinghouse, and would. (i) the enlarged part of the dwellinghouse would be within 2 metres of the boundary of the curtilage of the dwellinghouse, and the height of the eaves of the enlarged part would exceed 3 metres (ii) be within 7 metres of any boundary of the curtilage of the dwellinghouse opposite the rear wall of the dwellinghouse (i) extend beyond the rear wall of the original dwellinghouse by more than 3 metres, or (h) the enlarged part of the dwellinghouse would have more than a single storey and. (i) extend beyond the rear wall of the original dwellinghouse by more than 8 metres in the case of a detached dwellinghouse, or 6 metres in the case of any other dwellinghouse, or (g) until 30th May 2019, for a dwellinghouse not on article 2(3) land nor on a site of special scientific interest, the enlarged part of the dwellinghouse would have a single storey and. (i) extend beyond the rear wall of the original dwellinghouse by more than 4 metres in the case of a detached dwellinghouse, or 3 metres in the case of any other dwellinghouse, or (f) subject to paragraph (g), the enlarged part of the dwellinghouse would have a single storey and. (ii) fronts a highway and forms a side elevation of the original dwellinghouse (i) forms the principal elevation of the original dwellinghouse or (e) the enlarged part of the dwellinghouse would extend beyond a wall which. (d) the height of the eaves of the part of the dwellinghouse enlarged, improved or altered would exceed the height of the eaves of the existing dwellinghouse (c) the height of the part of the dwellinghouse enlarged, improved or altered would exceed the height of the highest part of the roof of the existing dwellinghouse (b) as a result of the works, the total area of ground covered by buildings within the curtilage of the dwellinghouse (other than the original dwellinghouse) would exceed 50% of the total area of the curtilage (excluding the ground area of the original dwellinghouse) (a) permission to use the dwellinghouse as a dwellinghouse has been granted only by virtue of Class M, N, P or Q of Part 3 of this Schedule (changes of use) Development not permittedĪ.1 Development is not permitted by Class A if. PART 1 Development within the curtilage of a dwellinghouse Class A – enlargement, improvement or other alteration of a dwellinghouse Permitted DevelopmentĪ. The enlargement, improvement or other alteration of a dwellinghouse. ![]()
0 Comments
Leave a Reply. |